Summary for Test 2024-04-20-9-1
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994730 DEA: 040Y1904 EFIS: 0422000255 |
---|---|
DIST-CO-RTE-PM | 04-SOL-37-R0.0/R7.4 |
Award Date | 06/27/2023 |
Closeout Date | Not set |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G. |
Location Description | SOLANO COUNTY IN AND NEAR VALLEJO FROM SONOMA COUNTY LINE TO NAPA RIVER BRIDGE |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 04/20/2024 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G Mix |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Lab Technician | Telephone number of sampler | 7072999133 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Vallejo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | 326128D |
Test Details
DIME Sample ID: 2024-04-20-9
DIME Test ID: 2024-04-20-9-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-04-25
Test Results
Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 04/20/2024
Specific Gravity for Sample 1: 2.395
Specific Gravity for Sample 2: 2.401
Average Specific Gravity: 2.398
Theoretical maximum density at 25°C (77°F): 2391 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/25/2024 ✔