Summary for Test 2017-06-05-6-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211931
DEA: 043G6414
EFIS: 0416000348
DIST-CO-RTE-PM04-NAP-29-37.0
Award Date03/17/2017
Closeout Date04/22/2020
Work DescriptionSCOUR REPLACE BRIDGE
Location DescriptionNAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
QA Service Level1 (Verified on 02/15/2017)

Sample Information

Sample Taken Date06/05/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/06/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byED Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Evraz Transportation Laboratory (TL) NumberC703734
Inspector Lot Number from the Transportation Laboratory (TL) FormB1020517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)589594
Hoop Manufacturer Lot Number(s)H04, H05 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEvraz
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-06-05-6
DIME Test ID: 2017-06-05-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-06-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/07/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11H05#5/16mm0.312987896380necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/7/2017