Summary for Test 2024-04-09-1-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994737
DEA: 081M1704
EFIS: 0821000086
DIST-CO-RTE-PM08-RIV-15,71,91,215-Var
Award Date06/30/2023
Closeout Date08/30/2024
Work DescriptionSTRUCTURAL CONCRETE AND POLYESTER CONCRETE OVERLAY.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date04/09/2024 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing04/16/2024 Sample typeQuality Assurance
A brief description of the sample2 pcs 3/4"x3" A325 Bolt Assemblies The quantity of what the sample constitutes15 Bolt Assemblies
From where was the sample collectedFabricator First name of sampler or witnessed byPreston
Last name of sampler or witnessed byBrockett Title of samplerQuality Assurance Inspector
Telephone number of sampler5627836180 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSt. Louis Screw & Bolt
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL175-025-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)V072059
Heat Number(s)10858270 Bolt 5805575204 Nut 32320750 Washer Nut Mfg. Lot Number(s)38614-5805575204
Washer Mfg. Lot Number(s)0623-771 Bolt SpecificationASTM A325-1
Bolt Length(s)3" Nut SpecificationASTM A563-DH
Washer SpecificationASTM F436-1 FinishPlain
Diameter/Size3/4" Bolt Mfg. Lot Number050513
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2024-04-09-1
DIME Test ID: 2024-04-09-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-04-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 04/17/2024
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A63966Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 4/19/2024 ✔