Summary for Test 2024-03-14-38-7

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994820
DEA: 060V1104
EFIS: 0616000208
DIST-CO-RTE-PM06-FRE,KIN-5,41,198-Var
Award Date08/31/2023
Closeout Date05/09/2025
Work DescriptionSTRATFORD KINGS RIVER BRIDGE REPLACEMENT.
Location DescriptionFRESNO AND KINGS COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/20/2023)

Sample Information

Sample Taken Date03/14/2024 Sample Unique Key38
Date that the sample was received by the laboratory/organization performing the testing03/15/2024 Sample typeQuality Control
A brief description of the sampleType T-II/V Cement The quantity of what the sample constitutes27.6
From where was the sample collectedManufacturer First name of sampler or witnessed byJimmy
Last name of sampler or witnessed byJuco Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameConFab California, LLC Shafter
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC_S8.5-0FG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected4532
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from wheelbarrow collected from chute of ready mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-03-14-38
DIME Test ID: 2024-03-14-38-7
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-06-12

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jesus Rodriguez
Date of test: 04/11/2024
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 1 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 127450 lb
Maximum load on cylinder 2: 137825 lb
Maximum load on cylinder 3: 135785 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Cross sectional area of cylinder 3: 12.56 in^2
Compressive strength (to nearest 10 psi): 10640 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/12/2024 ✔