Summary for Test 2023-10-12-71-1
Test performed: ASTM C430-8Project Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/12/2023 | Sample Unique Key | 71 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/12/2023 | Sample type | Annual Source Testing |
| A brief description of the sample | Silica Fume | The quantity of what the sample constitutes | 1 Bucket |
| From where was the sample collected | Source | First name of sampler or witnessed by | N/A |
| Last name of sampler or witnessed by | NA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM23N317 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Henan Abrasives Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | RED Industrial Products |
|---|---|---|---|
| Mill | Henan Abrasives _ 102 DSea | Type of Cementitious Material | Silica Fume |
Test Details
DIME Sample ID: 2023-10-12-71
DIME Test ID: 2023-10-12-71-1
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2024-03-20
Test Results
Type of Material: Hydraulic Cement
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 01/16/2024
Residue from the sample retained on the No. 325 sieve (Rs): 0.0016 grams
Sieve correction factor (C): 51.92
Corrected residue, % (Rc): 0.2 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 99.8 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2024 ✔