Summary for Test 2024-02-29-39-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 994944 DEA: 081J2304 EFIS: 0818000002 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-60-R1.0/12.0 |
| Award Date | 09/20/2023 |
| Closeout Date | 04/28/2025 |
| Work Description | RAMP METERING SYSTEM, HMA (TYPE A), RDWY EXC, MOD SIGNAL & LTG SYSTEMS |
| Location Description | RIVERSIDE COUNTY IN AND NEAR JURUPA VALLEY AND RIVERSIDE AT VARIOUS LOCATIONS FROM WINEVILLE ROAD UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 60/91 SEPARATION |
| QA Service Level | 1 (Verified on 07/28/2023) |
Sample Information
| Sample Taken Date | 02/29/2024 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/29/2024 |
| Sample type | Department Acceptance | A brief description of the sample | Native subgrade |
| The quantity of what the sample constitutes | 15.6 kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Maryanna | Last name of sampler or witnessed by | Landaverde |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | MVP #9 - Pedley Rd. 60 EB On-Ramp | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-02-29-39
DIME Test ID: 2024-02-29-39-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-03-13
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Maryanna Landaverde
Date of test: 03/01/2024
Sum of Count or Density: 4919 g/cc
Average of Count or Density: 1640 g/cc
Sum of Moisture Count: 373 g/cc
Average of Moisture Count: 124 g/cc
Count Ratio Density: 1
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 94.2 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%
Test was verified on 3/13/2024 ✔