Summary for Test 2017-05-08-2-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
| Award Date | 11/05/2015 |
| Closeout Date | 01/18/2022 |
| Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
| Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 05/08/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2017 |
| Sample type | Department Acceptance | A brief description of the sample | A325 TC Bolts 1x3 1x4 |
| The quantity of what the sample constitutes | 874.142 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
| Title of sampler | QA | Telephone number of sampler | 916-799-3391 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-131-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 378870A, 382078A |
|---|---|---|---|
| Heat Number(s) | DL16100848, DL16100843 | Nut Mfg. Lot Number(s) | 371124B, 369069B |
| Washer Mfg. Lot Number(s) | 030427, 030427 | Bolt Specification | A325 |
| Bolt Length(s) | 3", 4" | Nut Specification | 563 DH |
| Washer Specification | F436 | Finish | MG, MG |
| Diameter/Size | 1"x3", 1"x4" | Bolt Mfg. Lot Number | 378850A, 382040A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-05-08-2
DIME Test ID: 2017-05-08-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-05-26
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/16/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2A | S1913017 | 1\" | 84596 | 376.3 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 5/19/2017 ✔