Summary for Test 2024-01-25-40-4

Test performed: ASTM C566-19

Project Information

Project IdentifiersProject ID: 994116
DEA: 010J4104
EFIS: 0119000025
DIST-CO-RTE-PM01-HUM-299-30.7/33.4
Award Date11/23/2022
Closeout DateNot set
Work DescriptionProject Name: HUM-299 Curve Improvement
Location DescriptionHUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date01/25/2024 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/25/2024
Sample typeQuality Control A brief description of the sampleFine Agg - Sand
The quantity of what the sample constitutes50lbs From where was the sample collectedFabricator
First name of sampler or witnessed byDonald Last name of sampler or witnessed byJuneman
Title of samplerLab Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFolsom Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0061
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-01-25-40
DIME Test ID: 2024-01-25-40-4
Testing Lab: Universal Precast Concrete - Redding
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Test Release Date: 2024-02-13

Test Results


Input Type: Calculated
Tester's full name: Travis - MTI
Date of test: 01/26/2024
Total evaporable moisture content: 8.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/13/2024