Summary for Test 2024-01-15-31-1
Test performed: ASTM C231-17aProject Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 01/15/2024 | Sample Unique Key | 31 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/16/2024 |
| Sample type | Quality Control | A brief description of the sample | 4 x 8 concrete cylinders |
| The quantity of what the sample constitutes | 54 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Zack | Last name of sampler or witnessed by | Arnold |
| Title of sampler | Telephone number of sampler | 707-441-8855 | |
| Laboratory sample identification | C9060 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Eureka Ready mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | E675WRF |
|---|---|---|---|
| The truck number from where the sample was collected | 82 | The batch plant ticket number from where the sample was collected | 34117 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | Top Waler |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-15-31
DIME Test ID: 2024-01-15-31-1
Testing Lab: SHN Engineers & Geologists, Incorporated
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2024-02-12
Test Results
Is wet sieving required?: No
Input Type: Calculated
Tester's full name: Zack Arnold
Date of test: 01/15/2024
Air content: 4.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/12/2024 ✔