Summary for Test 2024-01-11-23-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994109
DEA: 060W1704
EFIS: 0617000103
DIST-CO-RTE-PM06-FRE-41-R27.4/R28.5
Award Date11/08/2022
Closeout DateNot set
Work DescriptionREMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location DescriptionFRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/13/2022)

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/12/2024
Sample typeQuality Assurance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes28.5 CY From where was the sample collectedJob Site
First name of sampler or witnessed byArthur Last name of sampler or witnessed byMills
Title of samplerConsultant Telephone number of sampler8033087727
Laboratory sample identification121 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBuilders Concrete Ready Mix Plant Sanger Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDS 2, 3, 4 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND10521
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected111336137
Concrete batch plantBuilders Sanger The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from BACK OF concrete truck CHUTE into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-11-23
DIME Test ID: 2024-01-11-23-3
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-09

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 02/09/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 48350 lb
Maximum load on cylinder 2: 46390 lb
Maximum load on cylinder 3: 47770 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 29 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 3846.5 psi
Compressive strength of cylinder 2: 3673.0 psi
Compressive strength of cylinder 3: 3764.4 psi
Compressive strength (to nearest 10 psi): 3760 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/9/2024