Summary for Test 2024-01-15-24-2
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 993705 DEA: 11056394 EFIS: 1117000151 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-11-2.7 |
| Award Date | 07/18/2022 |
| Closeout Date | 06/03/2024 |
| Work Description | CONSTRUCT DRAINAGE FACILITIES, RETAINING WALL AND EARTHWORK. |
| Location Description | SAN DIEGO COUNTY NEAR SAN DIEGO AT 1.9 MILES EAST OF SANYO AVENUE UNDERCROSSING. |
| QA Service Level | 1 (Verified on 05/04/2022) |
Sample Information
| Sample Taken Date | 01/15/2024 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/16/2024 |
| Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 1.85 yards | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Nicholas | Last name of sampler or witnessed by | Armijo |
| Title of sampler | QC Technician | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Thompson pipe group | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT 6001 DC |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 127630 | |
| Concrete batch plant | Eagan | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Chute discharge into wheel barrel | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-15-24
DIME Test ID: 2024-01-15-24-2
Testing Lab: Thompson Pipe Group - Los Angeles
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-02-08
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Nickolas Loagan
Date of test: 01/29/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.01 in
Maximum load on cylinder 1: 181500 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 14 days
Compressive strength of cylinder (to nearest 10 psi): 6400 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/8/2024 ✔