Summary for Test 2023-11-28-68-1
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 994405 DEA: 080F5414 EFIS: 0800000137 COOP: 081743 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-- |
| Award Date | 10/12/2022 |
| Closeout Date | Not set |
| Work Description | RIV 71/91 FLYOVER |
| Location Description | Not set |
| QA Service Level | 2 (Verified on 11/07/2022) |
Sample Information
| Sample Taken Date | 11/28/2023 | Sample Unique Key | 68 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/11/2023 | Sample type | Quality Control |
| A brief description of the sample | TYPE II / V | The quantity of what the sample constitutes | 10.50 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | JOEY |
| Last name of sampler or witnessed by | BUCKLER | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CEMEX-REDLANDS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1610974 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 31028545 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | SAMPLE FROM WHEELBARROW | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-11-28-68
DIME Test ID: 2023-11-28-68-1
Testing Lab: Surecast West
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-25
Test Results
Number of specimens: 3
Input Type: Calculated
Tester's full name: Cody Coppins
Date of test: 12/11/2023
Correction factor: 1
Cylinder Age: 14 days
Break Description of Cylinder 1 (if not 'cone'): no data
Break Description of Cylinder 2 (if not 'cone'): no data
Break Description of Cylinder 3 (if not 'cone'): no data
Average Compressive Strength (to nearest 10): 5830 lb/in^2
Compressive Strength of Cylinder 1: 72160 lb/in^2
Compressive Strength of Cylinder 2: 75550 lb/in^2
Compressive Strength of Cylinder 3: 71400 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/25/2024 ✔