Summary for Test 2023-12-27-20-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 993870
DEA: 120R5604
EFIS: 1218000117
DIST-CO-RTE-PM12-ORA-5,55,73,91,133,405-var
Award Date04/12/2023
Closeout Date08/19/2026
Work DescriptionPLACE RHMA-G, HMA, SLAB REPLACEMENT AND JPCP.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/14/2022)

Sample Information

Sample Taken Date12/27/2023 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing12/28/2023 Sample typeQuality Assurance
A brief description of the sampleConcrete beams The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byKenny
Last name of sampler or witnessed byDo Title of sampler
Telephone number of sampler9498727223 Laboratory sample identification23-0417
Linked DIME Sample ID The fabricator/manufacturer/facility nameSecurity Paving
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-23-PCC-345-HE
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledsta 28 94 to sta 42 00
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-12-27-20
DIME Test ID: 2023-12-27-20-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-01-24

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Dan Morris
Date of test: 01/24/2024
Identification number: 23-0417
Width of specimen: 6 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7420 lb
Maximum load applied 2: 8170 lb
Maximum load applied 3: 6870 lb
Curing history and apparent moisture condition of the specimen: Sand pit/Lime water bath (Contract Specs.)
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 640 psi
Modulus of rupture 2: 710 psi
Modulus of rupture 3: 590 psi
Modulus of rupture average: 650 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/24/2024 ✔