Summary for Test 2024-01-15-7-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
---|---|
DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
Award Date | 11/23/2022 |
Closeout Date | Not set |
Work Description | Project Name: HUM-299 Curve Improvement |
Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
Sample Taken Date | 01/15/2024 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2024 |
Sample type | Quality Assurance | A brief description of the sample | TYPE II/V CEMENT |
The quantity of what the sample constitutes | 3 4x8 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Tatjana | Last name of sampler or witnessed by | Halda |
Title of sampler | ASR | Telephone number of sampler | 707 599-5669 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Eureka Ready Mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 12-04E0054 | |
Structure name | RW B2 |
Material Information
Material Type | Concrete | The concrete mix design number | E675WRF |
---|---|---|---|
The truck number from where the sample was collected | 84 | The batch plant ticket number from where the sample was collected | 34121 |
Concrete batch plant | Arcata Eureka Ready Mix | The fabricator/manufacturer designation for the sample | Batch |
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | RW B2 Waler 1 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-15-7
DIME Test ID: 2024-01-15-7-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-22
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 01/22/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 32660 lb
Type of fracture pattern of cylinder 1: 6
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 2600 psi
General comments (publicly viewable) (Max 1000 characters): Lab cured cylinders 1 7 day break.
Test was verified on 1/22/2024 ✔