Summary for Test 2024-01-17-24-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994084 DEA: 060U8804 EFIS: 0616000074 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-26.3/27.6 |
Award Date | 01/23/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY |
Location Description | ON STATE ROUTE 99 |
QA Service Level | 1 (Verified on 03/13/2023) |
Sample Information
Sample Taken Date | 01/17/2024 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2024 |
Sample type | Department Acceptance | A brief description of the sample | Native Borrow |
The quantity of what the sample constitutes | 40 lbs native material | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SPCI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 test location | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-01-17-24
DIME Test ID: 2024-01-17-24-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-01-19
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 01/17/2024
Gage No.: 30697
Test No.: 30
Nuclear By: Neale Brown
Non-Bias Plan No.: 4 even
Depth: 8
Material No.: no data
Material Type: f-silt/clay mixture mod BRN
Impact By: Jason Ruiz
Standard Count Density: 1714 g/cc
Count or Density 1: 914 g/cc
Count or Density 2: 865 g/cc
Count or Density 3: 971 g/cc
Count or Density 4: 1008 g/cc
Count or Density 5: 981 g/cc
Standard Count Moisture: 634 g/cc
Moisture Count 1: 207 g/cc
Moisture Count 2: 218 g/cc
Moisture Count 3: 223 g/cc
Moisture Count 4: 218 g/cc
Moisture Count 5: 217 g/cc
Sum of Count or Density: 4739.00 g/cc
Average of Count or Density: 948.00 g/cc
Sum of Moisture Count: 1083.00 g/cc
Average of Moisture Count: 217.00 g/cc
Count Ratio Density: 0.55
Count Ratio Moisture: 0.34
Calculated Percent Relative Compaction: 94.6 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters): Commercial Ave Abut #1 Sta 27+30 to 26+82 elevation: 264.30ft-262.70ft width: 320ft Retest#1
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-0U8804_37039_240117_29to36 | 1969.08 KB | 01/19/2024 | 2024-01-17-24-1 | Info |
Test was verified on 1/19/2024 ✔