Summary for Test 2023-12-15-31-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994109
DEA: 060W1704
EFIS: 0617000103
DIST-CO-RTE-PM06-FRE-41-R27.4/R28.5
Award Date11/10/2022
Closeout DateNot set
Work DescriptionREMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location DescriptionFRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/13/2022)

Sample Information

Sample Taken Date12/15/2023 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/18/2023
Sample typeDepartment Acceptance A brief description of the samplePCC cylinders
The quantity of what the sample constitutes300 From where was the sample collectedJob Site
First name of sampler or witnessed byDavid Last name of sampler or witnessed byBorsch
Title of samplerAssistant Structure Representative Telephone number of sampler5596963263
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBuilders Concrete Ready Mix Plant Sanger Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSoil Nail Wall 3

Material Information

Material TypeConcrete The concrete mix design numberND22023
The truck number from where the sample was collected2 The batch plant ticket number from where the sample was collected111334925
Concrete batch plantBuilders Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWall 3 Wall Facing 4th Lift Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-12-15-31
DIME Test ID: 2023-12-15-31-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-12

Test Results


Unit system used?: SI Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 01/12/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4 mm
Average diameter of cylinder 2: 4 mm
Average diameter of cylinder 3: 4 mm
Maximum load on cylinder 1: 65870 N
Maximum load on cylinder 2: 67140 N
Maximum load on cylinder 3: 64460 N
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 mm^2
Cross sectional area of cylinder 2: 12.57 mm^2
Cross sectional area of cylinder 3: 12.57 mm^2
Compressive strength of cylinder 1: 5240.3 MPa
Compressive strength of cylinder 2: 5341.3 MPa
Compressive strength of cylinder 3: 5128.1 MPa
Compressive strength (to nearest 0.1MPa): 5236.6 MPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/12/2024