Summary for Test 2023-10-31-80-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 212246 DEA: 053307A4 EFIS: 0514000027 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-46-49.7/54.6 |
| Award Date | 02/16/2022 |
| Closeout Date | 09/02/2025 |
| Work Description | Cholame Segment |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 10/31/2023 | Sample Unique Key | 80 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/07/2023 |
| Sample type | Dispute Resolution | A brief description of the sample | 3/4" HMA-A w/15% RAP, WMA |
| The quantity of what the sample constitutes | 2 Boxes of HMA 1 Core | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Engen |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 023-095 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | SPM AVENAL | Transportation Laboratory (TL) Number | C992373 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 3 |
| Sublot number | 4 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-10-31-80
DIME Test ID: 2023-10-31-80-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-12-12
Test Results
Number of tests: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Water
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 12/11/2023
Method Performed: Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1: 2858.7 grams
Mass of sample in water for Sample 1: 1695.6 grams
Mass of oven-dry sample in air for Sample 2: 2651.9 grams
Mass of sample in water for Sample 2: 1572.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.458
Specific Gravity for Sample 2: 2.456
Average Specific Gravity: 2.457
Theoretical maximum density at 25°C (77°F): 2449.9 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/12/2023 ✔