Summary for Test 2017-04-14-3-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211794 DEA: 044G5104 EFIS: 0412000483 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-31.4,32.6 |
| Award Date | 01/20/2017 |
| Closeout Date | 09/12/2019 |
| Work Description | BRIDGE CONSTRUCTION |
| Location Description | SOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 01/03/2017) |
Sample Information
| Sample Taken Date | 04/14/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/18/2017 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Gary |
| Last name of sampler or witnessed by | MaComb | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | CMC Rebar |
| Transportation Laboratory (TL) Number | C970931 | Inspector Lot Number from the Transportation Laboratory (TL) Form | L1003717 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4065065 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 7 |
| Diameter of Hoop | 4'-7" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-14-3
DIME Test ID: 2017-04-14-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2017
UTM: 2000KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 1 | #7/22mm | 0.6 | 56400 | 94000 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/18/2017 ✔