Summary for Test 2023-11-17-2-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 214487 DEA: 120Q9304 EFIS: 1217000128 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5,133,241-122,241-var |
| Award Date | 05/09/2022 |
| Closeout Date | 12/01/2025 |
| Work Description | 12-0Q930, SHOPP RESERVATION BRIDGE PROJECT - BRIDGE UPGRADE, WINGWALL, SUBSTRUCTURE, DECK, SPALL, JOINT SEAL, CONC. |
| Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 12/10/2020) |
Sample Information
| Sample Taken Date | 11/17/2023 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/01/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 x 3-1/2 A325 Bolts |
| The quantity of what the sample constitutes | 400 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Telephone number of sampler | 3109128014 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cordova Bolt Inc. | Transportation Laboratory (TL) Number | L169-056-23 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Bolt- 10762840 Nut-8000022215 Washer- 32320750 Lock Washer- 10752420 | Nut Mfg. Lot Number(s) | W000037844 |
| Washer Mfg. Lot Number(s) | 168024, 0723-793, 202116-08 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 3-1/2 | Nut Specification | ASTM A 563 |
| Washer Specification | ASTM F436 | Finish | ASTM F2329 HDG |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | E028G1 |
| Rocap Test Requirement(s) | Sung Tight Connection, no rocap. | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-11-17-2
DIME Test ID: 2023-11-17-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-12-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/06/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 55804 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/12/2023 ✔