Summary for Test 2023-11-17-1-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 214487
DEA: 120Q9304
EFIS: 1217000128
DIST-CO-RTE-PM12-ORA-5,133,241-122,241-var
Award Date05/09/2022
Closeout DateNot set
Work Description12-0Q930, SHOPP RESERVATION BRIDGE PROJECT - BRIDGE UPGRADE, WINGWALL, SUBSTRUCTURE, DECK, SPALL, JOINT SEAL, CONC.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 12/10/2020)

Sample Information

Sample Taken Date11/17/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/01/2023
Sample typeQuality Assurance A brief description of the sample3/4 x 3 A325 High Strength Bolt Assembly
The quantity of what the sample constitutes400 From where was the sample collectedDistributor
First name of sampler or witnessed byJacob Last name of sampler or witnessed byGarcia
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3109128014
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL169-055-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt- 10828270, Nut-8000022215 Washer- 32320750 Lock Washer- 10752420 Nut Mfg. Lot Number(s)W000037844
Washer Mfg. Lot Number(s)0723-793, 20211608 Bolt SpecificationASTM A325
Bolt Length(s)3 Nut SpecificationASTM A 563
Washer SpecificationASTM F436 FinishASTM F2329 HDG
Diameter/Size3/4 Bolt Mfg. Lot NumberE234L1
Rocap Test Requirement(s)Sung Tight Connection, No rocap. Lubricant Requirements(s)

Test Details

DIME Sample ID: 2023-11-17-1
DIME Test ID: 2023-11-17-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-12-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/06/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B55975Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 12/12/2023