Summary for Test 2023-05-06-19-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994248
DEA: 051K1204
EFIS: 0518000125
DIST-CO-RTE-PM05-SCR-9-1.0,4.0
Award Date12/07/2022
Closeout Date09/02/2025
Work DescriptionCONSTRUCT SIDEHILL VIADUCTS.
Location DescriptionSANTA CRUZ COUNTY AT 0.5 MILE NORTH OF VERNON STREET AND AT 0.8 MILE SOUTH OF GLENGARRY ROAD
QA Service Level1 (Verified on 09/19/2022)

Sample Information

Sample Taken Date05/06/2023 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing05/06/2023 Sample typeQuality Control
A brief description of the sampleconcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedJob Site First name of sampler or witnessed byGregory
Last name of sampler or witnessed byCarr Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Rock
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number57S750
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected187491
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-05-06-19
DIME Test ID: 2023-05-06-19-3
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-12-05

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Gregory Carr
Date of test: 05/06/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 195590 lb
Maximum load on cylinder 2: 194740 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6900 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/5/2023 ✔