Summary for Test 2023-08-28-82-1
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 994731 DEA: 040Y3004 EFIS: 0422000265 |
---|---|
DIST-CO-RTE-PM | 04-SM-92-R10.4/R12.0 |
Award Date | 06/21/2023 |
Closeout Date | 03/04/2024 |
Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G. |
Location Description | SAN MATEO COUNTY IN AND NEAR SAN MATEO FROM 0.2 MILE WEST OF ALAMEDA DE LAS PULGAS OVERCROSSING TO 92/101 SEPARATION |
QA Service Level | 1 (Verified on 05/09/2023) |
Sample Information
Sample Taken Date | 08/28/2023 | Sample Unique Key | 82 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMA-G |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Holie | Last name of sampler or witnessed by | Sada |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Materials - Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Where material enters the drier drum mixer | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | 1 | |
Sublot number | 7 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-08-28-82
DIME Test ID: 2023-08-28-82-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-12-22
Test Results
How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Luis Magana
Date of test: 08/29/2023
Clay reading: 8.1
Sand reading: 4
Sand Equivalent: 50
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/22/2023 ✔