Summary for Test 2023-09-29-34-6
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 09/29/2023 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/29/2023 |
| Sample type | Quality Control | A brief description of the sample | PCC |
| The quantity of what the sample constitutes | 60 yards | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Gonzales |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | C8937 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Eureka Ready Mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Wall B3 | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | E675WRF |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 32477 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | back of truck | Where the material sample would have been placed if not sampled | Waler 1 Wall B3 |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-09-29-34
DIME Test ID: 2023-09-29-34-6
Testing Lab: SHN Engineers & Geologists, Incorporated
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-17
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dave Gonzales
Date of test: 11/10/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 60480 lb
Maximum load on cylinder 2: 63200 lb
Maximum load on cylinder 3: 64420 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4990 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/17/2024 ✔