Summary for Test 2023-09-29-52-6

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994116
DEA: 010J4104
EFIS: 0119000025
DIST-CO-RTE-PM01-HUM-299-30.7/33.4
Award Date11/23/2022
Closeout DateNot set
Work DescriptionProject Name: HUM-299 Curve Improvement
Location DescriptionHUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date09/29/2023 Sample Unique Key52
Date that the sample was received by the laboratory/organization performing the testing09/30/2023 Sample typeQuality Control
A brief description of the sample4x8 cylinders The quantity of what the sample constitutes60 cy
From where was the sample collectedJob Site First name of sampler or witnessed byDave
Last name of sampler or witnessed byGonzales Title of samplerspecial inspector
Telephone number of sampler707-599-5169 Laboratory sample identificationC8937
Linked DIME Sample ID The fabricator/manufacturer/facility nameEureka Ready mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameHwy 299 Soldier Pile Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberE675WRF
The truck number from where the sample was collected282 The batch plant ticket number from where the sample was collected32477
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete sample from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-29-52
DIME Test ID: 2023-09-29-52-6
Testing Lab: SHN Engineers & Geologists, Incorporated
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-11-08

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dave Gonzales
Date of test: 10/06/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 41720 lb
Type of fracture pattern of cylinder 1: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 3320 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/8/2023 ✔