Summary for Test 2023-10-06-51-2
Test performed: CTM 524-March 2013Project Information
Project Identifiers | Project ID: 993870 DEA: 120R5604 EFIS: 1218000117 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5,55,73,91,133,405-var |
Award Date | 04/12/2023 |
Closeout Date | Not set |
Work Description | PLACE RHMA-G, HMA, SLAB REPLACEMENT AND JPCP. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 06/14/2022) |
Sample Information
Sample Taken Date | 10/06/2023 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/06/2023 |
Sample type | Quality Assurance | A brief description of the sample | PCC Rapid set beams |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | G3 | Last name of sampler or witnessed by | G3 |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 23-0298 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Security Paving - Volumetric | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-21-CTS-220 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Location 12 at SB73 Connector to SB55 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-10-06-51
DIME Test ID: 2023-10-06-51-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2023-11-01
Test Results
Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Kenny Do
Date of test: 10/09/2023
Identification number: B23-0298-3-2
Width of specimen: 6 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 5.9375 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7000 lb
Maximum load applied 2: 7690 lb
Maximum load applied 3: 7530 lb
Curing history and apparent moisture condition of the specimen: Sand pit/Lime water bath (Contract Specs.)
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 600 psi
Modulus of rupture 2: 650 psi
Modulus of rupture 3: 650 psi
Modulus of rupture average: 630 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
B23-0298 | 222.45 KB | 11/01/2023 | 2023-10-06-51-2 | Info |
Test was verified on 11/1/2023 ✔