Summary for Test 2017-03-15-3-15
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/15/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/15/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 9 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Amy | Last name of sampler or witnessed by | Bihary |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Hodell-Natco Nucor Prestige | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 3263-031417 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 375883A | |
Washer Mfg. Lot Number(s) | D3205 | Bolt Specification | A325 |
Bolt Length(s) | 5.5 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1 | Bolt Mfg. Lot Number | 366321A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-03-15-3
DIME Test ID: 2017-03-15-3-15
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-03-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 03/20/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 375883A | 1\" | 94107 | 418.61 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest was verified on 3/21/2017 ✔