Summary for Test 2023-10-06-3-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994245
DEA: 051H4304
EFIS: 0516000073
DIST-CO-RTE-PM05-SB-101-21.4/21.9
Award Date03/02/2023
Closeout DateNot set
Work DescriptionSan Jose Creek Bridge replacement
Location DescriptionSANTA BARBARA COUNTY IN GOLETA FROM ROUTE 101/217 SEPARATION TO 0.3 MILE NORTH OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 09/19/2022)

Sample Information

Sample Taken Date10/06/2023 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/09/2023 Sample typeQuality Assurance
A brief description of the sample#6 1'-6 The quantity of what the sample constitutes10 Lots (1500 Hoops)
From where was the sample collectedFabricator First name of sampler or witnessed byLorenzo
Last name of sampler or witnessed byGarcia Title of samplerQuality Assurance Inspector
Telephone number of sampler17029172503 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL115-100-23
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202049061
Hoop Manufacturer Lot Number(s)Lots 45 and 51 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Utah
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-10-06-3
DIME Test ID: 2023-10-06-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-10-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 10/09/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13456/19mm0.4441029.5493249Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/12/2023 ✔