Summary for Test 2023-09-22-4-3

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date09/22/2023 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing09/26/2023 Sample typeQuality Assurance
A brief description of the sample#10 HRC 120 T Heads The quantity of what the sample constitutes8 headed bars
From where was the sample collectedFabricator First name of sampler or witnessed byHenry
Last name of sampler or witnessed byArredondo Title of samplerCaltrans Mets QA Inspector
Telephone number of sampler5623329603 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC Fountain Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL166-100-23
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)4132288 Head Manufacturer Lot Number(s)100012049345
Rebar Size#10 Headed Bar Model NameHRC 120 T Head
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Utah Cold Finish Division Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-03

Test Details

DIME Sample ID: 2023-09-22-4
DIME Test ID: 2023-09-22-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-09-28

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 09/26/2023
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.2712587799116Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/28/2023