Summary for Test 2023-09-09-4-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date09/09/2023 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing09/11/2023 Sample typeQuality Assurance
A brief description of the sample6x12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byErinberto
Last name of sampler or witnessed byAragon Title of samplerQA Atlas
Telephone number of sampler Laboratory sample identification1015-09 2023
Linked DIME Sample ID2023-07-21-24 The fabricator/manufacturer/facility nameLane Security Paving Joint Venture
Transportation Laboratory (TL) Number1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1613358
The truck number from where the sample was collected10064176 The batch plant ticket number from where the sample was collected30917353
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSIxth St. Bridge CIP Section deck concrete placement Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-09-4
DIME Test ID: 2023-09-09-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-09-20

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 09/14/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 102640 lb
Maximum load on cylinder 2: 103205 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 3670.0 psi
Compressive strength of cylinder 2: 3670.0 psi
Compressive strength (to nearest 10 psi): 3670 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/20/2023