Summary for Test 2023-09-04-2-2

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 994633
DEA: 120T6604
EFIS: 1222000076
DIST-CO-RTE-PM12-ORA-74-0.0/5.3
Award Date03/22/2023
Closeout Date07/01/2024
Work DescriptionCold plane AC pavement and place RHMA
Location DescriptionOrange County in and near San Juan Capistrano from Route 5/74 Separation to Gibby Road.
QA Service Level1 (Verified on 07/07/2023)

Sample Information

Sample Taken Date09/04/2023 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing09/18/2023 Sample typeVerification
A brief description of the samplePG Asphalt Binder The quantity of what the sample constitutes1 Quart Can
From where was the sample collectedSupplier First name of sampler or witnessed byHector Reyes QC
Last name of sampler or witnessed byHector Reyes QC Title of sampler
Telephone number of sampler Laboratory sample identification0479-23
Linked DIME Sample ID The fabricator/manufacturer/facility nameMM - Lake Elsinore
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2023-09-04-2
DIME Test ID: 2023-09-04-2-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2023-09-19

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 09/19/2023
Time of test: 8:30 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 80.0 %
Viscosity reading #1 (A) : 0.4 Pa-s
Viscosity reading #2 (B) : 0.404 Pa-s
Viscosity reading #3 (C): 0.405 Pa-s
Average viscosity: 0.403 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/19/2023 ✔