Summary for Test 2023-06-23-83-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 994243 DEA: 044J8404 EFIS: 0416000027 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-24-R3.4/R3.6 |
| Award Date | 11/28/2022 |
| Closeout Date | 11/27/2024 |
| Work Description | SEISMIC RESTORATION. |
| Location Description | CONTRA COSTA COUNTY IN ORINDA FROM 0.1 MILE WEST OF SAINT STEPHENS DRIVE OVERCROSSING TO 0.1 MILE EAST OF SAINT STEPHENS DRIVE OVERCROSSING. |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 06/23/2023 | Sample Unique Key | 83 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/26/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA-SP Type A W/25%RAP |
| The quantity of what the sample constitutes | 200TONS | From where was the sample collected | Source |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | 7072999133 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | De Silva Gates Drier Drum Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0007 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Same Pickup From Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 6741WM |
Test Details
DIME Sample ID: 2023-06-23-83
DIME Test ID: 2023-06-23-83-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-09-18
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 06/26/2023
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| 0 % | ||||||
| 0 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 95 % | ||||||
| 87 % | ||||||
| 60 % | ||||||
| 39 % | ||||||
| 28 % | ||||||
| 22 % | ||||||
| 19 % | ||||||
| 15 % | ||||||
| 14.1 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Sampled @ 200Tons.
Sieve#30, 200 FAILED
De Silva Gates Drier Drum Plant
W/25%RAP
Test was verified on 9/18/2023 ✔