Sample Record

Owner Lab

  • CT D04 - Concord Field Laboratory

DIME Sample ID 2023-06-23-83

Project Information

Project IdentifiersProject ID: 994243
DEA: 044J8404
EFIS: 0416000027
DIST-CO-RTE-PM04-CC-24-R3.4/R3.6
Award Date11/28/2022
Closeout DateNot set
Work DescriptionSEISMIC RESTORATION.
Location DescriptionCONTRA COSTA COUNTY IN ORINDA FROM 0.1 MILE WEST OF SAINT STEPHENS DRIVE OVERCROSSING TO 0.1 MILE EAST OF SAINT STEPHENS DRIVE OVERCROSSING.
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date06/23/2023 Sample Unique Key83
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2023
Sample typeQuality Assurance A brief description of the sample1/2-INCH HMA-SP Type A W/25%RAP
The quantity of what the sample constitutes200TONS From where was the sample collectedSource
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDe Silva Gates Drier Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSame Pickup From Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number6741WM

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-06-23-83-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)IGNACIO ARECHIGA, CT D04 - Concord Field Laboratory06/26/2023IGNACIO ARECHIGA
Yes
09/18/2023Sampled @ 200Tons. Sieve#30, 200 FAILED De Silva Gates Drier Drum Plant W/25%RAP
2023-06-23-83-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)IGNACIO ARECHIGA, CT D04 - Concord Field Laboratory06/26/2023IGNACIO ARECHIGA
Yes
09/18/2023Sand Reading=3.7 Clay Reading=5.5 SE Reading=68 PASSED

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-06-23-83-1 AASHTO T27-14 (Verified)
DIME Test ID: 2023-06-23-83-2 AASHTO T176-08 (Verified)