Summary for Test 2023-08-23-76-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993781
DEA: 07322404
EFIS: 0716000055
DIST-CO-RTE-PM07-LA-134-R12.6,R12.9
Award Date08/03/2022
Closeout Date03/13/2025
Work DescriptionREMOVE BRIDGE RAILING AND PLACE CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN PASADENA AT ARROYO SECO BRIDGE AND AT THE ORANGE GROVE BOULEVARD ON-RAMP OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date08/23/2023 Sample Unique Key76
Date that the sample was received by the laboratory/organization performing the testing09/05/2023 Sample typeQuality Assurance
A brief description of the sampleBarsplice Zap Screwlok Coupler The quantity of what the sample constitutes12
From where was the sample collectedJob Site First name of sampler or witnessed byPedro
Last name of sampler or witnessed byLabrada Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBarSplice
Transportation Laboratory (TL) Number07-322404-1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelDBL BRRL SCREWLOK CPLR
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)30802 Rebar Heat Number(s)4131051
Rebar Size 2 Coupler Unique IDSB-17-02

Test Details

DIME Sample ID: 2023-08-23-76
DIME Test ID: 2023-08-23-76-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-09-06

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 09/05/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 5/16mm200.312964195617Service Splice aauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/6/2023 ✔