Summary for Test 2023-07-19-31-2
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
---|---|
DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
Award Date | 04/19/2019 |
Closeout Date | 05/28/2024 |
Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 07/19/2023 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2023 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kreetha | Last name of sampler or witnessed by | Mekchai |
Title of sampler | Telephone number of sampler | 6265327705 | |
Laboratory sample identification | 23-0224 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CEMEX - ORANGE | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 1626505 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Lambert Rd Widen Stem and Soffit |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-07-19-31
DIME Test ID: 2023-07-19-31-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-09-01
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dan Morris
Date of test: 08/16/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 171620 lb
Type of fracture pattern of cylinder 1: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 6080 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/1/2023 ✔