Summary for Test 2023-08-25-29-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 994116
DEA: 010J4104
EFIS: 0119000025
DIST-CO-RTE-PM01-HUM-299-30.7/33.4
Award Date11/23/2022
Closeout DateNot set
Work DescriptionProject Name: HUM-299 Curve Improvement
Location DescriptionHUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date08/25/2023 Sample Unique Key29
Date that the sample was received by the laboratory/organization performing the testing08/28/2023 Sample typePer Request
A brief description of the sample3/8 Aggregates The quantity of what the sample constitutes2 bags coarse aggregate
From where was the sample collectedSupplier First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerQAI
Telephone number of sampler Laboratory sample identification23-PCCC-0163
Linked DIME Sample ID The fabricator/manufacturer/facility nameFolsom Ready Mix
Transportation Laboratory (TL) Numberna Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0061
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-25-29
DIME Test ID: 2023-08-25-29-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2023-09-01

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 08/30/2023
Top sediment column reading (single primary size): 0.7 in
Cleanness value (single primary size): 81
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/1/2023 ✔