Summary for Test 2023-08-16-3-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 993807 DEA: 07353304 EFIS: 0718000272 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-110-23.1 |
| Award Date | 11/03/2022 |
| Closeout Date | 09/24/2024 |
| Work Description | REPLACE BRIDGE RAILING WITH CONCRETE BARRIER. AND UPGRADE LIGHTING. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT THIRD STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 08/16/2023 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/16/2023 |
| Sample type | Department Acceptance | A brief description of the sample | Washed Concrete Sand |
| The quantity of what the sample constitutes | 16 CY | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Honesto | Last name of sampler or witnessed by | Castillo |
| Title of sampler | MREAS | Telephone number of sampler | 12134537563 |
| Laboratory sample identification | 041C | Linked DIME Sample ID | 2023-08-16-1 & 2023-08-16-2 |
| The fabricator/manufacturer/facility name | National Ready Mix Concrete-Vernon | Transportation Laboratory (TL) Number | C006702 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0052 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | 144 | A detailed description of where the material sample was collected | Belt Cut at Plant |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | S72500 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-08-16-3
DIME Test ID: 2023-08-16-3-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-08-29
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Honesto Castillo
Date of test: 08/16/2023
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 97 % | ||||||
| 86 % | ||||||
| 68 % | ||||||
| 44 % | ||||||
| 18 % | ||||||
| 5 % | ||||||
| 2 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/29/2023 ✔