Summary for Test 2023-05-31-63-5

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 993159
DEA: 08323034
EFIS: 0812000059
COOP: 081703
DIST-CO-RTE-PM08-RIV-60-18.8/19.6
Award Date05/04/2021
Closeout DateNot set
Work DescriptionProject Phase 2 (project) proposes to replace the existing hook ramp configuration along westbound (WB) SR-60 at the SR- 60/Moreno Beach Drive interchange with a partial cloverleaf configuration
Location DescriptionSR-60 & Moreno Beach Interchange
QA Service Level2 (Verified on 07/27/2021)

Sample Information

Sample Taken Date05/31/2023 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing06/16/2023 Sample typeVerification
A brief description of the sampleJMF 3/4" RHMA-G-SP 0.5% LAS The quantity of what the sample constitutes4 Bags Of Agg, 1 Bag each of Scrap & Hi-Nat
From where was the sample collectedManufacturer First name of sampler or witnessed byVictor
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0322G-23
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt- Perris
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at All American Perris
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number106835 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-05-31-63
DIME Test ID: 2023-05-31-63-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-09-12

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: M.Landaverde
Date of test: 06/28/2023
Clay Level (Test 1): 4.7
Sand Level (Test 1): 3.7
Clay Level (Test 2): 4.7
Sand Level (Test 2): 3.6
Clay Level (Test 3): 4.9
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 79
Sand Equivalent (Test 2): 77
Sand Equivalent (Test 3): 78
Sand Equivalent: 78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/12/2023 ✔