Summary for Test 2023-06-15-40-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 215666 DEA: 11430564 EFIS: 1119000015 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-67-R6.0/24.4 |
| Award Date | 03/01/2022 |
| Closeout Date | 11/04/2024 |
| Work Description | COLD PLANE, RHMA OVERLAY AND HFST, AND INSTALL CHANNELIZERS. |
| Location Description | SAN DIEGO COUNTY NEAR LAKESIDE AND RAMONA FROM 0.2 MILE NORTH OF SAN DIEGO RIVER BRIDGE TO ROUTE 78 |
| QA Service Level | 1 (Verified on 07/06/2021) |
Sample Information
| Sample Taken Date | 06/15/2023 | Sample Unique Key | 40 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/19/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G |
| The quantity of what the sample constitutes | 12 boxes 2 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 21218080SR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-06-15-40
DIME Test ID: 2023-06-15-40-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2023-07-18
Test Results
Unit system used?: SI Units
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 07/05/2023
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
| 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | |
| 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | |
| 3695.9 g | 3680.7 g | 3700.7 g | 3683.4 g | 3691.8 g | 3676.9 g | |
| 2082.7 g | 2073.1 g | 2083.2 g | 2069.5 g | 2085.7 g | 2064.4 g | |
| 3705.7 g | 3696.9 g | 3712.8 g | 3696.5 g | 3711.6 g | 3688.1 g | |
| 2.444 | 2.444 | 2.444 | 2.444 | 2.444 | 2.444 | |
| 3777.3 g | 3766.0 g | 3784.7 g | ||||
| 2082.7 g | 2073.1 g | 2083.2 g | ||||
| 95.1 mm | 95.1 mm | 95.2 mm | ||||
| 130 mmHg | 125 mmHg | 90 mmHg | ||||
| 0 inHg | 0 inHg | 0 inHg | ||||
| 0 minutes | 0 minutes | 0 minutes | ||||
1623.0 cm^3 | 1623.8 cm^3 | 1629.6 cm^3 | 1627.0 cm^3 | 1625.9 cm^3 | 1623.7 cm^3 | |
2.277 | 2.267 | 2.271 | 2.264 | 2.271 | 2.265 | |
6.8 % | 7.2 % | 7.1 % | 7.4 % | 7.1 % | 7.3 % | |
110.4 cm^3 | 116.9 cm^3 | 115.7 cm^3 | 120.4 cm^3 | 115.4 cm^3 | 118.5 cm^3 | |
3773.2 g | 3762.5 g | 3781.7 g | ||||
3784.2 g | 3774.2 g | 3793.3 g | ||||
1694.6 cm^3 | 1692.9 cm^3 | 1701.5 cm^3 | ||||
81.4 cm^3 | 85.3 cm^3 | 84.0 cm^3 | ||||
74 % | 73 % | 73 % | ||||
4.4 % | 4.3 % | 4.4 % | ||||
16565 N | 15840 N | 15030 N | 16921 N | 19554 N | 18295 N | |
1 | 1 | 1 | 1 | 1 | 1 | |
6 | 4 | 1 | 3 | 2 | 5 | |
0 | 0 | 0 | 0 | 0 | 0 | |
739 kPa | 707 kPa | 670 kPa | 756 kPa | 874 kPa | 817 kPa | |
102 psi | 118 psi | |||||
0.86 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/18/2023 ✔