Summary for Test 2023-05-23-79-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993773
DEA: 021H5004
EFIS: 0216000045
DIST-CO-RTE-PM02-TRI-3,299-VAR
Award Date11/14/2022
Closeout Date06/19/2025
Work DescriptionSTRUCT CONC BRIDGE, POLYESTER CONC OVERLAY & ROCK SLOPE PROTECTION.
Location DescriptionTRINITY COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/25/2022)

Sample Information

Sample Taken Date05/23/2023 Sample Unique Key79
Date that the sample was received by the laboratory/organization performing the testing06/02/2023 Sample typeQuality Assurance
A brief description of the sampleStainless Steel Couplers The quantity of what the sample constitutes16
From where was the sample collectedManufacturer First name of sampler or witnessed byNA
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade75 Rebar ManufacturerNorth American Stainless
Coupler ManufacturerCMC Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelTru Splice
Coating StandardsASTM A123 galvanized Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)NA Rebar Heat Number(s)V56K-RA71565
Rebar Size 2 Coupler Unique IDNot on AML

Test Details

DIME Sample ID: 2023-05-23-79
DIME Test ID: 2023-05-23-79-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-06-30

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 06/29/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 6/19mm1-0.00360.4446294105214Service Splice Broke in Threadsaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice Broke in Threads
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 6/30/2023 ✔