Summary for Test 2023-04-03-14-4

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/03/2023 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing04/03/2023 Sample typeAuthorization
A brief description of the sampleType II Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM23N302
Linked DIME Sample ID The fabricator/manufacturer/facility nameXuan Thanh Cement
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandMartin Marietta
MillXuan Thanh Type of Cementitious MaterialType II/V Cement

Test Details

DIME Sample ID: 2023-04-03-14
DIME Test ID: 2023-04-03-14-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2023-05-17

Test Results


Input Type: Calculated
Tester's full name: Anthony Valdez
Date of test: 04/19/2023
Type of Water Used: Type IV grade reagent water
Initial time of setting: 123 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/17/2023 ✔