Summary for Test 2023-04-18-105-23

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 215649
DEA: 043G4884
EFIS: 0412000088
DIST-CO-RTE-PM04-SM-92-R14.4/R18.8
Award Date09/01/2022
Closeout Date10/09/2024
Work DescriptionCLEAN AND PAINT STEEL BRIDGE TOWERS, REPLACE HIGH STRENGTH BOLTS.
Location DescriptionSAN MATEO COUNTY IN FOSTER CITY FROM SAN MATEO-HAYWARD BRIDGE TO ALAMEDA COUNTY LINE
QA Service Level1 (Verified on 03/29/2021)

Sample Information

Sample Taken Date04/18/2023 Sample Unique Key105
Date that the sample was received by the laboratory/organization performing the testing04/20/2023 Sample typePer Request
A brief description of the sampleA325 Bolt The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byGilel
Last name of sampler or witnessed byKlebanov Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA325 Bolt
Bolt Length(s)2.75 - 4.5 Nut SpecificationNA
Washer SpecificationNA Finish
Diameter/Size Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2023-04-18-105
DIME Test ID: 2023-04-18-105-23
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2023-05-16

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 05/16/2023
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BNA0.875067850301.8110.00A325 wedge tensile Pier 23 Srmacias

General comments (publicly viewable) (Max 1000 characters): A325 wedge tensile Pier 23 S
Test Graph
Source: Bluehill Data Point File

Test was verified on 5/16/2023 ✔