Summary for Test 2022-09-07-38-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 993629
DEA: 112N0874
EFIS: 1119000220
DIST-CO-RTE-PM11-SD-5,15,76,78-Var
Award Date05/27/2022
Closeout Date02/27/2024
Work DescriptionPPLY METHACRYLATE, PLACE POLYESTER CONCRETE OVERLAY Apply Methacrylate on bridge deck
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/21/2022)

Sample Information

Sample Taken Date09/07/2022 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/07/2022
Sample typeQuality Control A brief description of the sample2 pints 204,chp,,8020
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler17076245467
Laboratory sample identification943124 Linked DIME Sample ID943124
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)22-90-391490
Batch number2290391490 Mix number2290391490

Test Details

DIME Sample ID: 2022-09-07-38
DIME Test ID: 2022-09-07-38-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2023-05-03

Test Results


Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 05/03/2023
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.5
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 25
Flash point (ASTM D 3828) more than 180 deg F: 180
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 779.8
Tack free time, 400 minutes max: 352
General comments (publicly viewable) (Max 1000 characters): Accepted Suppliers Bond and Tack Free Time.

Test was verified on 5/3/2023