Summary for Test 2023-04-15-6-3
Test performed: ASTM C293-10Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 04/15/2023 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/16/2023 | Sample type | Quality Assurance |
| A brief description of the sample | cast concrete beams | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | julian |
| Last name of sampler or witnessed by | Carmora | Title of sampler | C3 |
| Telephone number of sampler | Laboratory sample identification | set 8 A B C | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | LANEsecurity paving | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-21-PRS-238R |
|---|---|---|---|
| The truck number from where the sample was collected | TIME 2150HR | The batch plant ticket number from where the sample was collected | TIME 2150 HR |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | At the plant | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-04-15-6
DIME Test ID: 2023-04-15-6-3
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Test Release Date: 2023-04-26
Test Results
Unit system used?: US Units
Input Type: Calculated
Tester's full name: Julius E
Date of test: 04/25/2023
Identification number: set 8J (C)
Width of specimen: 6 inch
Depth of specimen: 6.125 inch
Span length of specimen: 18 inch
Maximum load applied: 10515 lb
Curing history and apparent moisture condition of the specimen: CURING ROOM
If specimen was capped, ground or if leather shims were used: NO
Defects in specimen: NO
Age of specimen: 10 days
Modulus of rupture: 880 psi
General comments (publicly viewable) (Max 1000 characters): AVE 847 PSI FOR 650 PSI @ 10 DAYS BREAK
Test was verified on 4/26/2023 ✔