Summary for Test 2023-04-18-4-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215649 DEA: 043G4884 EFIS: 0412000088 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-92-R14.4/R18.8 |
| Award Date | 09/01/2022 |
| Closeout Date | 10/09/2024 |
| Work Description | CLEAN AND PAINT STEEL BRIDGE TOWERS, REPLACE HIGH STRENGTH BOLTS. |
| Location Description | SAN MATEO COUNTY IN FOSTER CITY FROM SAN MATEO-HAYWARD BRIDGE TO ALAMEDA COUNTY LINE |
| QA Service Level | 1 (Verified on 03/29/2021) |
Sample Information
| Sample Taken Date | 04/18/2023 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1"x4" F1852 A325 TC Bolt Assemblies |
| The quantity of what the sample constitutes | 1200 bolts | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dylan | Last name of sampler or witnessed by | LaRose |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Unytite Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10809160, 20847310, 125841 | Nut Mfg. Lot Number(s) | 37908-20847310 |
| Washer Mfg. Lot Number(s) | 1222-565 | Bolt Specification | F3125/A325TC |
| Bolt Length(s) | 4" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mech Galv |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 37885-10809160 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-04-18-4
DIME Test ID: 2023-04-18-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-05-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 04/26/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 94665 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 5/8/2023 ✔