Summary for Test 2022-09-02-35-1
Test performed: ASTM D2196-Feb15Project Information
| Project Identifiers | Project ID: 215682 DEA: 031H1904 EFIS: 0316000065 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-80,244-M9.6/12.9,0.0/T0.8 |
| Award Date | 06/18/2021 |
| Closeout Date | 04/07/2025 |
| Work Description | COLD PLANE AC PAVEMENT, PLACE RHMA AND INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | SACRAMENTO COUNTY IN AND NEAR SACRAMENTO ON ROUTE 80 FROM 0.2 MILE EAST OF LONGVIEW DRIVE OVERCROSSING TO 0.4 MILE EAST OF MADISON AVENUE OVERCROSSING AND ON ROUTE 244 FROM 0.3 MILE NORTH OF AUBURN BOULEVARD TO CONNECTOR TO ROUTE 80 |
| QA Service Level | 1 (Verified on 05/17/2021) |
Sample Information
| Sample Taken Date | 09/02/2022 | Sample Unique Key | 35 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/06/2022 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can |
| The quantity of what the sample constitutes | 32 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 17076245467 |
| Laboratory sample identification | 943123 | Linked DIME Sample ID | 943123 |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | High Friction Surface Treatment | Mgf. Lot Number(s) | 1426034 |
|---|---|---|---|
| Batch Number | 1426034 | Mix Number | 1426034 |
| Resin Binder Type | Polyester | Used for Overlay | Yes |
| Used for Inlay | No |
Test Details
DIME Sample ID: 2022-09-02-35
DIME Test ID: 2022-09-02-35-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Test Release Date: 2023-03-29
Test Results
Input Type: Calculated
Tester's full name: Rachael Chavez
Date of test: 09/22/2022
Viscosity: 1904
General comments (publicly viewable) (Max 1000 characters): Gel time ASTM C881=25 mins.
Cure rate ASTM D1640=1.23 hrs.
Test was verified on 3/29/2023 ✔