Summary for Test 2023-02-18-10-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 215003
DEA: 040J6204
EFIS: 0414000019
DIST-CO-RTE-PM04-ALA-680-12.4/21.9
Award Date04/12/2022
Closeout DateNot set
Work DescriptionREHABILITATE PAVEMENT - RPL APP/DEP SLABS, 14 BRIDGES
Location DescriptionALAMEDA COUNTY AT SUNOL AND IN PLEASANTON AND DUBLIN FROM KOOPMANN ROAD UNDERCROSSING TO ALAMEDA COUNTY LINE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date02/18/2023 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/01/2023
Sample typeQuality Assurance A brief description of the samplePCC sample for CRCP
The quantity of what the sample constitutes162CY From where was the sample collectedSource
First name of sampler or witnessed byRobert Last name of sampler or witnessed byLohman
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSecurity Paving Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-22-PRS-319
The truck number from where the sample was collected18 The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plantVulcan Portable plant The fabricator/manufacturer designation for the sampleVulcan
A detailed description of where the material sample was collectedConcrete sample from loader bucket Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-02-18-10
DIME Test ID: 2023-02-18-10-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2023-03-22

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 03/01/2023
Identification number: set 1
Width of specimen: 5.9375 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 6.125 inch
Depth of specimen: 6.1875 inch
Depth of specimen 2: 5.3125 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 740 psi
Maximum recording 2: 750 psi
Maximum recording 3: 730 psi
Correction Factor: 0.96
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: Water cure in Cure Tank
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 750 psi
Modulus of rupture 2: 790 psi
Modulus of rupture 3: 770 psi
Modulus of rupture average: 770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/22/2023