Summary for Test 2016-11-07-3-7

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211391
DEA: 074T7104
EFIS: 0714000209
DIST-CO-RTE-PM07-LA-66-2.9
Award Date06/17/2016
Closeout Date07/05/2017
Work DescriptionINSTALL TRAFFIC AND PEDESTRIAN SIGNALS.
Location DescriptionLOS ANGELES COUNTY IN POMONA AT SUMNER AVENUE
QA Service Level1 (Verified on 06/06/2016)

Sample Information

Sample Taken Date11/07/2016 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing11/10/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes12
From where was the sample collectedFabricator First name of sampler or witnessed byGary
Last name of sampler or witnessed byMaComb Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar Nucor Cascade
Transportation Laboratory (TL) NumberC970389 Inspector Lot Number from the Transportation Laboratory (TL) FormL1013016
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL16201954, 001916
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#4,5,5
Diameter of Hoop2'-2", 2'-8", 3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Cascade
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-11-07-3
DIME Test ID: 2016-11-07-3-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-11-16

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/16/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
142 3\'-2\"#5/16mm0.312921094230Bar Broke in Heat Affected AreaFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area; OK Necking; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 11/16/2016 ✔