Summary for Test 2016-10-03-3-3

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date10/03/2016 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/06/2016 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes8
From where was the sample collectedJob Site First name of sampler or witnessed byHUNG
Last name of sampler or witnessed byNgo Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification889-03W
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJobsite
Transportation Laboratory (TL) Number889-03W Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameBURBANK WESTERN CHANNEL PRECAST PRESTESSED DECK PANELS GROUP 12
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS72035
The truck number from where the sample was collected494 The batch plant ticket number from where the sample was collected202204
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedDischard fron concrete truck into wheelbarrow. Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-10-03-3
DIME Test ID: 2016-10-03-3-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-11-16

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 11/14/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 134870 lb
Maximum load on cylinder 2: 136470 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4754.0 psi
Compressive strength of cylinder 2: 4795.2 psi
Compressive strength (to nearest 10 psi): 4770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2016