Summary for Test 2022-10-25-66-6

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/25/2022 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2022
Sample typeAnnual Source Testing A brief description of the sampleType II/V Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM225281 Linked DIME Sample ID
The fabricator/manufacturer/facility nameLehigh Tehachapi Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandLehigh
MillTehachapi Type of Cementitious MaterialType II/V Cement

Test Details

DIME Sample ID: 2022-10-25-66
DIME Test ID: 2022-10-25-66-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2023-01-04

Test Results


Input Type: Calculated
Tester's full name: Anthony Valdez
Date of test: 12/09/2022
Type of Water Used: Type IV grade reagent water
Initial time of setting: 179 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/4/2023