Summary for Test 2022-11-15-51-5
Test performed: AASHTO T316-17Project Information
| Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
| Award Date | 11/26/2019 |
| Closeout Date | 11/01/2023 |
| Work Description | Remove concrete pavement and base, and place HMA and JPCP |
| Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
| QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
| Sample Taken Date | 11/15/2022 | Sample Unique Key | 51 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/16/2022 |
| Sample type | Department Acceptance | A brief description of the sample | PG Asphalt Binder |
| The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Martin Marietta QC | Last name of sampler or witnessed by | Martin Marietta QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0740-22 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Martin Marietta (CCA) Lake Elsinore | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Wilmington CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2022-11-15-51
DIME Test ID: 2022-11-15-51-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2022-12-21
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 12/16/2022
Time of test: 9:50 HH:MM
Test Temperature: 135.0 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 74.0 %
Viscosity reading #1 (A) : 0.752 Pa-s
Viscosity reading #2 (B) : 0.74 Pa-s
Viscosity reading #3 (C): 0.742 Pa-s
Average viscosity: 0.745 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/21/2022 ✔